Skip to product information
1 of 1

Apc

APC AP8841 RACK PDU 2G, Metered, ZEROU, 30A, 200/208V, (36) C13 & (6) C19 Output Connections Metered Rack PDU

APC AP8841 RACK PDU 2G, Metered, ZEROU, 30A, 200/208V, (36) C13 & (6) C19 Output Connections Metered Rack PDU

Returns / Exchanges: Sealed Product Only

SKU:731304277002

Regular price $1,230.33 CAD
Regular price $0.00 CAD Sale price $1,230.33 CAD
Sale Sold out
Shipping calculated at checkout.

PRODUCT DESCRIPTION
APC AP8841 Rack PDU 2G/ Metered/ Zero U/ 30A/ 208V Surge Protector

FROM THE MANUFACTURER

SUPERIOR EQUIPMENT AND DATA PROTECTION
WHY BUY APC BY SCHNEIDER ELECTRIC?
Over the years, APC by Schneider Electric has received hundreds of awards worldwide - more than any other power protection manufacturer. Such designations have recognized APC by Schneider Electric for both its reliable solutions and its overall business performance.

RACK PDU 2G, METERED, ZEROU, 30A, 200/208V, (36) C13 & (6) C19
Metered rack PDUs provide real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit overloads before critical IT failures occur.

APC by Schneider Electric Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. New AP8000 series Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers.

User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, Command Line Interface, or Telnet Interfaces which are complimented by Schneider Electric's StruxureWare solution.

Metered Rack PDU Features & Benefits Availability Remote Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Local Current Monitoring Display The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. Alarm Thresholds Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment). Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability) Load indicator LED Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. Flash Upgradeable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Technical Specifications Output Nominal Output Voltage 208V Maximum Total Current Draw per Phase 24A Output Connections (36) IEC 320 C13 (6) IEC 320 C19 Overload Protection Yes Input Nominal Input Voltage 208V Input Frequency 50/60 Hz Regulatory Derated Input Current (North America) 24A Input Connections NEMA L6-30P Cord Length 2, 74 meters Number of Power Cords 1 Acceptable Input Voltage 200-240 VAC Maximum Input Current per phase 30A Physical Net Weight 6.84 kg Maximum Height 1791.00 mm Maxiumum Width 56.00 mm Maximum Depth 44.00 mm Shipping Weight 8.47 kg Shipping Height 2000.00 mm Shipping Width 162.00 mm Shipping Depth 107.00 mm Color Black Environmental Operating Environment -5 - 45 °C Operating Relative Humidity 5 - 95% Operating Elevation 0 - 3000 meters Storage Temperature -25 - 65 °C Storage Relative Humidity 5 - 95% Storage Elevation 0 - 15,000 meters Conformance Regulatory Approvals CSA C22.2 No. 60950, IEC 60950, METI Denan, UL 60950-1, VDE Standard Warranty 2 years repair or replace Sustainable Offer Status RoHS Compliant REACH REACH: Contains No SVHCs Battery Directive Compliant Battery Notes Contains Lithium Battery

Shipping Policy

1. PO Box Address Policy:

  • We do not ship to PO Box addresses. Customers must provide a valid residential or commercial address during checkout.
  • If a PO Box address is provided, the order will be canceled, and we will not capture your pending payment.

2. Delivery Failure Due to Customer Fault:

  • If the delivery failure is attributed to customer-related factors, such as providing an incorrect shipping address or failure to receive the package, Dealtargets.com will not be held responsible for the unsuccessful delivery.
  • Customers are responsible for ensuring that the shipping information provided is accurate and for being available to receive the package during the designated delivery times.
  • Any additional costs incurred due to delivery failure caused by customer fault, including but not limited to redelivery fees, will be borne by the customer.

3. Adult Signature Requirement and Shipping Address Policy:

  • All shipments processed through Dealtargets.ca require an adult signature upon delivery. Customers must ensure that a person of legal age is available to sign for the package upon its arrival.
  • Once a parcel has been shipped, Dealtargets.ca does not entertain requests for changing the shipping address. Customers must provide accurate and up-to-date shipping information during checkout.
  • Any issues arising from failure to adhere to these policies, such as missed deliveries or address changes after shipment, will be the sole responsibility of the customer.

Return Policy for Non-Defective Items

Due to Manufacturer Requirements: We are unable to offer returns for opened, non-defective products. This policy adheres to manufacturer requirements, and no exceptions can be made.

Eligibility: To qualify for a return or exchange, the product must be in its factory-sealed condition or remain in its original shipping box.

Proof of Purchase: A proof of purchase, such as a receipt or order confirmation email, must accompany the returned product. For detailed information, refer to our Return and Refund Policy.

Manufacturer Warranty

Coverage: All items are covered by the manufacturer's warranty. Customers are required to contact the manufacturer directly for any warranty-related concerns. For more information, please visit our Product Warranty Policy.

View full details